PATSONS ENERGY

Generator manufacturer · Dubai, UAE

Generator sets engineered and assembled in the UAE.

Prime, standby and multi-set power systems from 100 to 3,000 kVA, developed around the load, site, acoustic target and control requirement.

100–3,000 kVAProject range
50 / 60 HzFrequency options
Prime + standbyDuty ratings
Dubai assembledLocal project control

Power-system range

Specify the package, not only the kVA.

Patsons coordinates generator selection, mechanical packaging, acoustic treatment, controls and testing as one project scope.

Technicians checking an open generator set and its control panel
Representative engineering and quality-control workflow.

UAE engineering & assembly

One team from technical submittal to site start-up.

Local assembly keeps drawings, fabrication, controls and inspection connected. Project changes can be reviewed against the physical package before dispatch.

  • Package assemblyEngine, alternator, cooling, base frame and auxiliaries integrated in Dubai.
  • Custom fabricationAcoustic enclosures, containers, tanks, drip trays and service-access details.
  • Controlled testingFunctional checks, load-bank testing and project witness points.
  • Lifecycle supportCommissioning, planned service, breakdown response and spare parts.
Explore UAE manufacturing

Initial specification brief

Start with four decisions.

Use this brief to organize the first discussion. Patsons will still verify the load profile, derating and project interfaces before confirming a model.

Application-led design

Power systems for demanding operating environments.

The duty, risk and site conditions shape the engineering decisions behind each generator package.

Critical facilities

Redundancy, rapid start, step-load response and maintainability.

Industrial plants

Motor starting, process continuity, ventilation and service access.

Oil & gas

Hazardous-area interfaces, shutdowns, coating and traceability.

Construction

Prime duty, transport, dust, fuel autonomy and changing loads.

Marine & ports

Corrosion protection, restricted access and lifting constraints.

Commercial standby

Automatic operation, acoustic targets and service planning.

Selected project record

Multi-megawatt delivery experience.

Patsons’ published prequalification record spans large UAE and export projects, from individual sets to coordinated generator plants.

Review selected projects
25 MVA20 × 1,250 kVA export project
20.22 MVARuwais, UAE project
15 MVA60 × 250 kVA development project
13.4 MVAUmm Al Quwain island project

Request a technical quote

A useful proposal starts with a useful brief.

Send what is available. The team will identify the missing technical inputs before configuration is finalized.

  • Required kVA or connected load
  • Prime or standby duty
  • Voltage and frequency
  • Site and acoustic conditions
  • Required date and project stage

Prefer to discuss it?

+971 4 347 4781 info@alshola.com

Technical enquiry

Send the requirement

Fields marked * are required.

Contact
Requirement

Your details are used only for this enquiry.

Frequently asked questions

Before you request a generator quote

Final selections and compliance are confirmed against the project specification and approved technical submittal.

What generator range does Patsons Energy offer?

Patsons develops prime and standby generator projects from 100 to 3,000 kVA. The final rating is confirmed against the selected engine, alternator, frequency, voltage, ambient conditions and load profile.

Are Patsons generator sets assembled in the UAE?

Yes. Patsons engineers, assembles and packages generator systems at its manufacturing facility in Dubai Industrial City.

Can Patsons build soundproof and containerized generators?

Yes. The company manufactures sound-attenuated enclosures, custom containers, base frames, tanks and integrated packages with ventilation, exhaust, controls and service access.

Can Patsons synchronize multiple generators?

Yes. Multi-set projects can include synchronization, active and reactive load sharing, sequencing, load management and remote monitoring interfaces.